Procedure for construction of foundation starts with a decision on its depth, width, and marking layout for excavation and centerline of foundation. Foundation is the part of the structure below the plinth level in direct contact of soil and transmits ...
Design
Home/Design/Page 2Do you need to remove the ads? Get the paid membership
Discy Latest Articles
Reinforced Concrete Beam Detailing According to ACI Code
Clearly, the detailing of the reinforced concrete members is the key to good design and execution of work at the site.That is why poor detailing of reinforcement makes the structure undergo cracking, excessive deflection, or even collapse. Reinforcements resist tensile ...
DESIGN OF STONE COLUMNS BY HEINZ J. PRIEBES METHOD
What is stone columns? Why it is required? It is a technique adopted for the soil which didn’t have the sufficient characteristics to permit construction. The stone column technique, also known as vibro-replacement or vibro-displacement, is a ground improvement process ...
Types of Design and Detailing Errors in Construction and their Prevention
Common design and detailing errors in construction arises due to either inadequate structural design or due to lack of attention to relatively minor design details. Types of Design and Detailing Errors in Construction and their Prevention Following are the different ...
Isolated Footing Design Example and Excel Sheet
Isolated footing design example with step by step procedure and isolated footing design excel sheet (spreadsheet) is also provided for easy and fast calculation. Learning design with examples is always the best method of learning. Step by step procedure for ...
LOW COST FERROCEMENT EARTHQUAKE RESISTANT HOUSE
mind the cost efficiency, availability of materials, quick time of fabrication and flexibility of extension and portability.
No level of earthquake preparedness can guarantee that an earthquake will not damage a building. Structures cannot be completely earthquake-proof, but good seismic design will minimize structural damage, and the most importantly, safeguard the lives of the occupants during a major seismic event. Seismic resistance is best achieved by following modern building codes and standards and in large or complex.
Isolated Footing Design Guidelines and Specifications as per IS 456: 2000
Specifications for Design of footings as per IS 456: 2000 Isolated footings are designed to sustain the applied loads, moments and forces and the induced reactions and to ensure that any settlement which may occur is as nearly uniform as ...
Different Failure Modes of Concrete Columns – Compression Members
There are three modes of failure of concrete columns (compression members) i.e. failure due to pure compression, combined compression and elastic instability. These modes of failures of concrete compression members are discussed.