Concrete Cover Specifications for Reinforcement in Different Codes

Reading time: 1 minute

Concrete cover is assumed to be the first measure considered to prevent influences of aggressive elements on the reinforcement steel bars. That is why utmost cautions are needed during concrete cover thickness design and its construction. Commonly, the thickness of concrete cover is specified based on the type of the reinforced concrete member and the environment in which the structure is constructed. In this article, concrete cover specifications based on various most commonly used codes will be discussed. The specification of different codes regarding concrete cover is commonly dependent on nature of the structure, method of construction, environmental factors around the structure, and quality of concrete utilized in the construction. Determination of Concrete cover thickness according to the specifications of the following codes will be explored:

Concrete Cover Specifications as per ACI code

The American code institute (ACI 318-11) provides minimum concrete cover thickness for different elements of reinforced concrete structure. These minimum concrete covers can be found in the Table 1. The ACI code specifies certain condition in which this minimum cover thickness would not be adequate and hence it needs to be increased. These conditions include corrosive environment, fire protection, and future extension. For example, for reinforced concrete member subjected to sea water, the ACI code specifies that thickness of concrete cover should be at least 50mm. It is desired to set minimum thickness of concrete cover as 65mm to account for possible construction errors and hence make sure that 50mm cover thickness is achieved. The code allows the use of cover thickness smaller than those provided in Table-1 for precast concrete members.

Table-1: Minimum Cover Thickness for Cast-in-Place Concrete

Type of structure Concrete over, mm
Concrete cast against and permanently in contact with ground 75
Concrete in contact with ground or water
No. 19 through No. 57 bars 50
No. 16 bar and smaller 40
Concrete not exposed to weather or in contact with ground
Slabs, walls, joists
No. 43 and No. 57 bars 40
No. 36 bar and smaller 20
Beams, columns
Primary reinforcement, ties, stirrups, spirals 40
Shells, folded plate members
No. 19 bar and larger 20
No. 16 bar and smaller 13

Concrete Cover Specifications as per European Code

The euro code provides exact recommendation and details regarding the thickness of concrete cover. The code specified minimum concrete cover along with water to cement ratio, concrete strength, and minimum cement content based on the type of weather condition to which the structure is exposed. This can be clearly observed in Table-2 that provided minimum concrete cover thickness along with other parameters based on the weather condition.

Table-2: Minimum concrete cover according to the European code and British specifications

Exposure condition Maximum W/C ratio Minimum cement content, Kg/m3 Minimum concrete cover, mm Concrete grade
Dry 0.65 260 15 C30/37
Humid
No frost 0.60 280 20 C30/37
Frost 0.55 280 25 C35/45
De-icing salts 0.5 300 40 C35/45
Seawater
No frost 0.55 300 40 C35/45
Frost 0.50 300 40 C35/45
Aggressive chemicals
Slightly 0.55 280 25 -
Moderately 0.50 300 30 -
Highly 0.45 300 40 -
It is proven by number of researchers like Browne et. el. and Van Daver that concrete cover in majority of structures are less than that specified in design. For example, Browne et. el. reported that average cover thickness of observed structures was 13.9mm instead of 25mm that specified in the design. That is why European code states that minimum cover thickness should be increased by permitted standard deviation which ranges from 5-10mm for cast in situ concrete and 0-5mm for precast concrete.

Concrete Cover Specifications as per British standard

According to the British standard thickness of concrete cover is based on weather condition in which the structure is constructed. In addition to the concrete strength, and quality of concrete that is dependent on cement content and water to cement ratio. Table-3 provides minimum concrete cover thickness determined according to the British standard.

Table-3: Thickness and properties of concrete cover according to British standard

Environmental conditions Concrete grade, MPa
30 35 40 45 50
Water/ cement ratio
0.65 0.60 0.55 0.50 0.45
Minimum cement content, Kg/m3
25 20 20 20 20
Concrete cover thickness
Moderate1 25 20 20 20 20
Moderate2 --- 35 30 25 20
Hard3 --- --- 40 30 25
Very hard4 --- --- 50 40 30
Maximum condition5 --- --- --- 60 50
1 concrete surface protected from external weather or hard condition 2 concrete surfaces protected from rain or freezing and concrete under water or concrete adjacent to no affected soil 3concrete surface exposed to rain and wetting and drying 4concrete exposed to seawater spray or melting ice by salt or freezing 5concrete surface exposed to abrasion such as seawater containing solid particles, or moving water at pH 4.5 or machines or cars

Special specifications for structures subjected to considerably sever conditions

Commonly, offshore structures are directly subjected to sea water and specific protection measure should be considered to prevent corrosion of embedded steel bars. There are three major regions of severe weather condition to which reinforced concrete structure may be exposed. These severe weather conditions include air, splash zone, and immersed in water. The most dangerous condition is the splash zone since the structure subjected to seawater and air combination. ACI 357 provides recommendation regarding cover thickness in severe weather conditions based on the concrete strength, location of structure, and maximum water to cement ratio, see Table 4.

Table-4: ACI 357 recommendations for cover thickness in offshore structure

Location Maximum w/c ratio Minimum concrete strength at 28 days Cover thickness
Reinforced steel Prestressed
Air 0.4 35 50 75
Splash zone 0.4 35 65 90
Immersed in water 0.45 35 50 75
Apart from ACI 357, British standard provides recommendation about the selection of concrete cover thickness for private structures. The determination of concrete cover thickness takes several parameters into consideration for example degree of mixing for each concrete quality, life expectancy of the structure, and chloride diffusion factor in concrete. Read More: Minimum Concrete Cover for Reinforcement