Sign Up

Join TheConstructor to ask questions, answer questions, write articles, and connect with other people. When you join you get additional benefits.

Have an account? Sign In


Have an account? Sign In Now

Sign In

Log in to TheConstructor to ask questions, answer people’s questions, write articles & connect with other people. When you join you get additional benefits.

Sign Up Here

Join for free or log in to continue reading...


Forgot Password?

Don't have account, Sign Up Here

Forgot Password

Lost your password? Please enter your email address. You will receive a link and will create a new password via email.

Have an account? Sign In Now

Sorry, you do not have a permission to ask a question, You must login to ask question. Get the paid membership

Join for free or log in to continue reading...


Forgot Password?

Don't have account, Sign Up Here
Get the paid membership
theconstructor.org Logo theconstructor.org Logo
Log inJoin

theconstructor.org

theconstructor.org Navigation

  • Articles
    • Recent Articles
    • Popular Articles
    • Write for us
  • Community
  • Categories
    • How To Guide
      • Material Testing Guide
    • Concrete
    • Building
      • Brick Masonry
      • Building Materials
      • Building Tips
    • Construction
      • Equipments
      • Management
    • Digital Construction
    • Geotechnical
      • Foundation
  • Case Studies
Search
Ask A Question

Mobile menu

Close
Ask a Question
  • Questions
  • Ask Questions
  • Write for us
  • Artificial Intelligence
  • Sustainability
  • Building
    • Brick Masonry
    • Building Materials
    • Building Tips
    • Formwork/Shuttering
  • Concrete
    • Concrete Admixtures
    • Cement
    • Concrete Cracks
    • Concrete Properties
  • Construction
    • Construction Equipments
    • Construction Management
    • Construction Project
    • Estimating & Costing
  • How To Guide
    • Material Estimation
    • Repair/Protection Guide
    • Material Testing Guide
    • Mix Design Guide
    • Rate Analysis
  • Geotechnical
    • Foundation Engineering
    • Ground Improvement
  • Structural Engineering
    • Strengthening of Structure
    • Structual Inspection
    • Structural Detailing
  • Surveying
  • Tips

Structural Engineering

Home/Structural Engineering/Page 6

Do you need to remove the ads? Get the paid membership

  • Recent Questions
  • Most Answered
  • Answers
  • No Answers
  • Most Visited
  • Most Voted
  • Random

Discy Latest Questions

Asked: January 11, 2019In: Structural Engineering

What are the options of rebaring of a new column into an existing 150mm slab

Jude Oseafiana
Jude Oseafiana

Jude Oseafiana

  • 1 Question
  • 0 Answers
  • 0 Best Answers
  • 20 Points
View Profile
Jude Oseafiana User

How to construct a concrete column over existing slab of 150mm?

  1. aviratdhodare

    aviratdhodare

    • 37 Questions
    • 252 Answers
    • 0 Best Answers
    • 480 Points
    View Profile
    aviratdhodare
    Added an answer on October 3, 2020 at 11:23 am

    But why you want a column raised on a slab. The moment you do, a point load will come on slab at that point so it is not possible/advisable. Describe problem for alternative solution. You can't build a column on slab unless slab is designed for the load you needed for. It is regarded as pt load on sRead more

    But why you want a column raised on a slab. The moment you do, a point load will come on slab at that point so it is not possible/advisable. Describe problem for alternative solution.
    You can’t build a column on slab unless slab is designed for the load you needed for. It is regarded as pt load on slab which is usually not designed for it, it all relies on what purpose you want to raise the column on slab.

    See less
    • 31
    • Share
      Share
      • Share on Facebook
      • Share on Twitter
      • Share on LinkedIn
      • Share on WhatsApp
  • 0
  • 2 2 Answers
  • 2,421 Views
  • 0 Followers
Asked: December 28, 2018In: Structural Engineering

How to calculate stiffness of storey to avoid soft storey?

sbandi67
sbandi67

sbandi67

  • 1 Question
  • 0 Answers
  • 0 Best Answers
  • 20 Points
View Profile
sbandi67 User

How to calculate stiffness of storey to avoid soft storey of multi-storeyed building?

  1. Kuldeep Singh

    Kuldeep Singh

    • 1 Question
    • 110 Answers
    • 10 Best Answers
    • 652 Points
    View Profile
    Kuldeep Singh Learner
    Added an answer on July 3, 2020 at 10:52 pm

    Avoid soft storey? A soft storey is a storey with lateral stiffness less than the storey just above. So technically, you cannot avoid soft storey just by calculation. Right? Well, according to the new code for seismic design, IS 1893 Part I (2016), infill masonry walls in soft storeys of RC buildingRead more

    Avoid soft storey? A soft storey is a storey with lateral stiffness less than the storey just above. So technically, you cannot avoid soft storey just by calculation. Right?

    Well, according to the new code for seismic design, IS 1893 Part I (2016), infill masonry walls in soft storeys of RC buildings can be modeled as diagonal struts to contribute to lateral stiffness.Though this doesn’t guarantee that the resulting storey stiffness with the contribution of infill walls, will be greater than that of the storey above.

    Method :

    • In buildings with RCC moment resisting frames with a soft storey (stiffness irregularity), when the structural plan density (SPD) of masonry infills exceeds 20%, the effect of unreinforced masonry infills (URM infills) has to be considered explicitly using structural analysis especially for buildings in earthquake zones III, IV and V.
    • The compressive strength, fª of URM infill prism is calculated as per IS 1905 or according to the formula in IS 1893 (2016) clause 7.9.2.1.
    • The URM infill walls are modelled as diagonal struts with ends pin jointed to the RC frames. The width of the struts are calculated as per clause 7.9.2.1 of IS 1893 (2016). Thickness, t is taken as equal to the thickness of the URM walls themselves provided h/t < 12 and l/t < 12 where h and t are the clear height and clear length of the diagonal struts.
    • The stiffnesses of the diagonal struts are added to the earlier floor stiffness and the new storey stiffness is calculated. If soft storey condition ceases, we can proceed with further analyses.

    [Note : Even after reading the answer please do refer to table 6, fig. 4 and section 7.9 of IS 1893 Part I (2016) for two formulae mentioned above and a clearer understanding of the method in detail.]

    See less
    • 0
    • Share
      Share
      • Share on Facebook
      • Share on Twitter
      • Share on LinkedIn
      • Share on WhatsApp
  • 2
  • 1 1 Answer
  • 2,289 Views
  • 0 Followers
Asked: July 19, 2020In: Structural Engineering

Why Earth pressure at rest is used for basement slab wall, bridge abutment?

vivek gami
vivek gami

vivek gami

  • 54 Questions
  • 16 Answers
  • 5 Best Answers
  • 93 Points
View Profile
vivek gami User

Why Earth pressure at rest is used for basement slab wall, bridge abutment?

  1. AdityaBhandakkar

    AdityaBhandakkar

    • 12 Questions
    • 250 Answers
    • 2 Best Answers
    • 0 Points
    View Profile
    AdityaBhandakkar User
    Added an answer on September 7, 2020 at 6:12 pm

    If the wall is rigid and cannot be move when the pressure exerted on the wall, then the soil behind the wall is in the state of static equilibrium. This case is called rest earth pressure. For bridges, slab walls and Abutments is soil mass or backfill with static equilibrium is required because it cRead more

    If the wall is rigid and cannot be move when the pressure exerted on the wall, then the soil behind the wall is in the state of static equilibrium. This case is called rest earth pressure.

    For bridges, slab walls and Abutments is soil mass or backfill with static equilibrium is required because it can bear the heavy load. Thus for safety point of view in construction pressure at rest is considered. In this case, all the pressures are being exerted uniformly on the retaining wall.

    There are two types of conditions developed

    For normally consolidated clay,

    K= 1- sin(¢)

    For overconsolidated clay

    K(overconsolidated )= K(normally consolidated clay) x √OCR 

    OCR= OVERCONSOLIDATION RATIO

    See less
    • 44
    • Share
      Share
      • Share on Facebook
      • Share on Twitter
      • Share on LinkedIn
      • Share on WhatsApp
  • 0
  • 2 2 Answers
  • 2,210 Views
  • 0 Followers
Asked: September 19, 2020In: Structural Engineering

What is a convergent beam? Why is it so important?

aviratdhodare
aviratdhodare

aviratdhodare

  • 37 Questions
  • 252 Answers
  • 0 Best Answers
  • 480 Points
View Profile
aviratdhodare

What is a convergent beam? Why is it so important?

  1. Komal Bhandakkar

    Komal Bhandakkar

    • 49 Questions
    • 255 Answers
    • 0 Best Answers
    • 2,050 Points
    View Profile
    Komal Bhandakkar AUTHOR
    Added an answer on November 20, 2020 at 3:46 pm
    This answer was edited.

    A convergent beam of light: Whenever several rays coming from different directions & meet at a single point are nothing but the Light's convergent beam. Thank You.

    A convergent beam of light:

    Whenever several rays coming from different directions & meet at a single point are nothing but the Light’s convergent beam.

    Thank You.

    See less
    • 1
    • Share
      Share
      • Share on Facebook
      • Share on Twitter
      • Share on LinkedIn
      • Share on WhatsApp
  • 30
  • 3 3 Answers
  • 2,097 Views
  • 0 Followers
Asked: November 22, 2017In: Structural Engineering

What are the steps for design of an isolated footing?

Gopal Mishra
Gopal Mishra

Gopal Mishra

  • 75 Questions
  • 44 Answers
  • 7 Best Answers
  • 577 Points
View Profile
Gopal Mishra

What are the steps for design of an isolated footing?

  • 0
  • 0 0 Answers
  • 2,074 Views
  • 0 Followers
Asked: September 25, 2020In: Structural Engineering

How do I remove a load bearing wall and extend?

aviratdhodare
aviratdhodare

aviratdhodare

  • 37 Questions
  • 252 Answers
  • 0 Best Answers
  • 480 Points
View Profile
aviratdhodare

How do I remove a load bearing wall and extend (extension only on one side) the ground floor on a g+1 structure, and what will be the costing of this procedure?

  1. nikeetasharma

    nikeetasharma

    • 23 Questions
    • 303 Answers
    • 0 Best Answers
    • 2,680 Points
    View Profile
    nikeetasharma Guru
    Added an answer on November 25, 2020 at 1:18 pm

    A floor plan should be provided with sections showing column and beam layout. But it will be better if you hire a contractor.

    A floor plan should be provided with sections showing column and beam layout. But it will be better if you hire a contractor.

    See less
    • 0
    • Share
      Share
      • Share on Facebook
      • Share on Twitter
      • Share on LinkedIn
      • Share on WhatsApp
  • 31
  • 3 3 Answers
  • 2,042 Views
  • 0 Followers
Asked: July 20, 2020In: Structural Engineering

What is fatigue in any structural member?

vivek gami
vivek gami

vivek gami

  • 54 Questions
  • 16 Answers
  • 5 Best Answers
  • 93 Points
View Profile
vivek gami User

What is fatigue in any structural member?

  1. nikeetasharma

    nikeetasharma

    • 23 Questions
    • 303 Answers
    • 0 Best Answers
    • 2,680 Points
    View Profile
    nikeetasharma Guru
    Added an answer on December 17, 2020 at 3:08 pm

    Concrete fatigue refers to the phenomenon of rupture under repeated loadings, each of which is smaller than a single static load that exceeds the strength of material.

    Concrete fatigue refers to the phenomenon of rupture under repeated loadings, each of which is smaller than a single static load that exceeds the strength of material.

    See less
    • 0
    • Share
      Share
      • Share on Facebook
      • Share on Twitter
      • Share on LinkedIn
      • Share on WhatsApp
  • 3
  • 6 6 Answers
  • 2,006 Views
  • 0 Followers
Asked: September 8, 2020In: Structural Engineering

What is the introductory rate analysis of SS Masonry?

aviratdhodare
aviratdhodare

aviratdhodare

  • 37 Questions
  • 252 Answers
  • 0 Best Answers
  • 480 Points
View Profile
aviratdhodare

What is the introductory rate analysis of SS Masonry?

  1. Komal Bhandakkar

    Komal Bhandakkar

    • 49 Questions
    • 255 Answers
    • 0 Best Answers
    • 2,050 Points
    View Profile
    Komal Bhandakkar AUTHOR
    Added an answer on November 20, 2020 at 3:47 pm
    This answer was edited.

    The rate analysis varies from place to place & it depends on the cost of construction material as well as labor cost. Roughly, we can say Ru. 134 per Cft. Required when PCC of 1:4:8 is used.

    The rate analysis varies from place to place & it depends on the cost of construction material as well as labor cost.

    Roughly, we can say Ru. 134 per Cft. Required when PCC of 1:4:8 is used.

    See less
    • 0
    • Share
      Share
      • Share on Facebook
      • Share on Twitter
      • Share on LinkedIn
      • Share on WhatsApp
  • 33
  • 2 2 Answers
  • 1,988 Views
  • 0 Followers
Load More Questions

Sidebar

Explore

  • Questions
  • Ask Questions
  • Write for us
  • Artificial Intelligence
  • Sustainability
  • Building
    • Brick Masonry
    • Building Materials
    • Building Tips
    • Formwork/Shuttering
  • Concrete
    • Concrete Admixtures
    • Cement
    • Concrete Cracks
    • Concrete Properties
  • Construction
    • Construction Equipments
    • Construction Management
    • Construction Project
    • Estimating & Costing
  • How To Guide
    • Material Estimation
    • Repair/Protection Guide
    • Material Testing Guide
    • Mix Design Guide
    • Rate Analysis
  • Geotechnical
    • Foundation Engineering
    • Ground Improvement
  • Structural Engineering
    • Strengthening of Structure
    • Structual Inspection
    • Structural Detailing
  • Surveying
  • Tips

Footer

  • Ask Questions
  • Write for us
  • Popular Questions
  • Facebook
  • Instagram
  • Twitter
  • Telegram

© 2009-2021 The Constructor. All Rights Reserved.