DISTANCE OF BUILDINGS FROM ELECTRIC LINES No verandah, balcony, saiban or the like be allowed to be erected or re-erected or any additions or alterations made to a building with the distances (quoted below) as per the current Indian Electricity Rules and its amendments from time to time between the buildings and any overhead electric(…)
Building Bye Laws
FACTORIES AND INDUSTRIAL BUILDING REGULATIONS
Notwithstanding any provisions provided, in any one of these bye-laws, every factory building or part thereof shall comply with the following additional regulations: a) Site: The location of every factory site shall be governed by the provisions of the development plan. For cities having no development plans, the factory site shall have to be approved(…)
REGULATION FOR PROJECTIONS FROM BUILDINGS
Projections from Buildings No projections of any sort what so ever extending more than 23 cm below a height of 4.3m, such as projection on the level of chajja, cornice, water spouts, drains, pipes, advertisement boards and the like shall project over the land of the road or over any drain of the vertical part(…)
OPEN SPACE REQUIREMENTS FOR BUILDINGS
OPEN SPACE REQUIREMENTS (Table 3) Open air space for ventilation. Every room intended for human habitation should abut an interior or exterior opening air space of the width r dimensions specified below. Table – 3 Where height of building above plinth adjoining the open air space does not exceed Minimum width of open air space(…)
REQUIREMENTS OF STAIRCASE & BATHROOMS
Requirements of staircase and bathrooms other than lighting and ventilation are given here. Other requirements of staircase: The minimum clear width of staircase in case of residential buildings shall not be less than 1m. In case of a public building, a staircase not less than 1.2m in width should be provided for 600 persons or(…)
LIGHTING AND VENTILATION REQUIREMENTS OF ROOMS
LIGHTING AND VENTILATION OF ROOMS a) Rooms: Every habitable room which should have for the admission of air and light, one or more apertures such as windows and fanlights, opening directly to the external air or into an open verandah and of an aggregate area, inclusive of frames, of not les than i. One-tenth of(…)
HEIGHT & SIZE REGULATIONS FOR ROOMS
Height Regulation: Habitable rooms: The minimum height from the surface of the floor to the ceiling or bottom of slab should be not les than 2.75m. For air-conditioned rooms, a height of not less than 2.4 m measured from the top of the floor to the lowest point of the air-conditioning duct or the false(…)
PLINTH AREA AND PLINTH REGULATION OF THE BUILDING
Plinth Area The minimum area of buildings of different classes shall be governed by the following: In an industrial plot, the plinth area should not exceed 60% of the site area. In a market area, the plinth area should not exceed 75% of the area of site, provided sufficient off-street parking facilities for loading and(…)